2022-09-23 12:39:09
BTS621L1 is a high-side power switch with integrated vertical power FET providing embedded protection and diagnostics
The BTS621L1 is a high-side power switch with integrated vertical power FETs that provide embedded protection and diagnostics. N-Channel Vertical Power FET with Charge Pump, Ground Referenced CMOS Compatible Input and Diagnostic Feedback, Monolithic SmartSAPMOS Technology. Provides embedded protection.
feature
Overload protection
current restrictions
Short circuit protection
Thermal shutdown
Overvoltage protection (including load dump)
Fast demagnetization of inductive loads
Reverse battery protection 1)
Undervoltage and Overvoltage Shutdown
Auto restart and lag
Open-drain diagnostic output
Turn on load detection in ON state
CMOS compatible input
Ground loss and Vbb protection loss
Electrostatic discharge (ESD) protection
Green Product (RoHS Compliant)
AEC qualified
application
C compatible power switch with diagnostic feedback for 12 V and 24 V DC grounded loads All types of resistive, inductive and capacitive loads
Replacement of electromechanical relays, fuses and discrete circuits
Product Summary
Overvoltage protection Vbb (AZ) 43 V.
Operating voltage Vbb(on) 5.0...34 V.
channel: each
parallel
On-resistance RON 10050m 61527 ;
Load current (ISO) IL (ISO) 4.4 8.5 A
Current Limit IL (SCr) 8 8 A.
Pin symbol function
1 OUT1 (load, L) output 1, protect the high-side power output of channel 1
2 GND logic ground
3 IN1 input 1, activates channel 1 in the presence of a logic high signal
4 Vbb positive supply voltage,
Label shorted to this pin
5 ST diagnostic feedback: open drain, low fault
6 IN2 Input 2, activates channel 2 in the presence of a logic high signal
7 OUT2 (load, L) output 2, high-side power output for protection channel 2
Status output diagram
ESD Zener: 6.1 V typical, 5 mA max; RST(ON) < 380 , 1.6 mA, ESD Zener is not
Used as a voltage clamp under DC conditions. Operating in this mode may cause the Zener diode to drift (increase to 1 V).
Inductor and Overvoltage Output Clamp Diagram
VON is clamped to 47 V (typ).
Open Detection: On-state Diagnostic Condition: VON OFF-STATE DIAGNOSTIC CONDITIONS: VOUT > 3 V (typ); at low GND disconnected any kind of load. If input = high, then VOUTVIN - VIN(T+). Since VGND > 0, there is no VST = low signal available.