2022-09-24 22:18:33
The TMP117MAIDRVT temperature sensor is designed for thermal management and thermal protection applications
1 function
1? TMP117 high precision temperature sensor
-±0.1°C (max) from -20°C to +50°C
-±0.15°C (max) from -40°C to +70°C
-±0.2°C (max) from -40°C to +100°C
-±0.25°C (max) from -55°C to +125°C
-±0.3°C (max) from -55°C to +150°C
?Operating temperature range: -55°C + 150°C
?Low power consumption:
- 3.5-µa, 1-Hz conversion period
- 150-nA shutdown current
? Power supply range: 1.8 - 5.5 V
?16-bit resolution: 0.0078°C (1 LSB)
? Programmable temperature alarm limits
?Select Average
?Digital offset for system correction
?General purpose EEPROM: 48 bits
?NIST traceability
?SMBus?, I
2c interface compatibility
2 applications
?Medical Grade: Complies with ASTM E1112 and ISO standards
80601-2-56
? Environmental monitoring and thermostats
? this set
?Asset tracking and cold chain
?Gas and heat meters
?Test and Measurement
?RTDs replacement: PT100, PT500, PT1000
? Thermocouple cold junction compensation
Gasket
3 Description
TMP117 is a high precision digital temperature
sensor. It is designed to meet ASTM E1112 and ISO standards
80601 Electronic Patient Requirements
thermometer. TMP117 provides 16-bit
Temperature resolution 0.0078°C and results
Accuracy to ±0.1°C temperature
The range is -20°C to 50°C without calibration. of
The interface of TMP117 is I
2c- and SMBus?-
compatible, programmable alarm functions, and
One device can support up to 4 devices
bus. The device comes with an integrated EEPROM
Programming with additional 48-bit memory
Available for general use.
Low power consumption of TMP117
Minimize the effect of self-heating on measurements
accuracy. The TMP117 operates from 1.8 V to 5.5 V
Typically consumes 3.5µA.
For non-medical applications, the TMP117 can serve
A platinum RTD as a digital replacement for a microcontroller.
The accuracy of the TMP117 is comparable to that of its peers
AA RTD while using only a fraction of the power
The power typically required by a PT100 RTD. of
TMP117 simplifies design by removing
The many complexities of RTDs such as precision
References, matching trajectories, complex algorithms,
and calibration.
TMP117 units are 100% tested in production
NIST Trackable and Verifiable Settings
ISO/IEC17025 Compliant Equipment
Certification standards